7
Use a suitable ash vacuum device to remove any ash deposited in the brazier
(fig. 6)
and around the brazier
(fig.
7).
WARNING: use suitable ash vacuum devices equipped with a fine mesh filter in order to prevent ash from being blown into the room and
to prevent damaging the vacuum cleaner. We do not recommend the use of normal vacuum cleaners.
Non-routine cleaning
The extraordinary cleaning of the appliance must be done at least every 30 days so as to always guarantee efficient performance and optimal operation.
Please proceed as follows:
Perform routine cleaning;
8
Remove the cast iron top, undoing the two screws shown in the picture
(fig.
8).
10
9
After having removed the two inspection plates in the picture
(fig.
9), clean the right and left flue gas conduits with a brush
(fig.
10).