Télécharger Imprimer la page

klover AURA 100 Instructions D'utilisation page 49

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
CS.A80.IST-1 / Rev 1.0
CLEANING AND MAINTENANCE
Precautions before cleaning
Before carrying out any cleaning or maintenance operations, make sure that:
-
the appliance is off and has cooled down completely;
-
the ash is completely cold.
-
the ash vacuum device used for cleaning is suitable and its filter is in good condition.
Before re-starting the appliance, re-install all previously removed components.
During cleaning operations, use the personal protection devices specified in Directive 89/391/EEC.
The required cleaning frequency depends on the type and quality of the pellets used. The schedule indicated below may therefore vary.
Any problem affecting the appliance caused by lack of cleaning will not be covered by the warranty. The failure of these operations could
affect the safety of the product.
Cleaning operations may be carried out by the end user, as indicated in the paragraph below.
Routine cleaning
The ordinary cleaning of the appliance must be done at least every 30 hours of operation or after 6-8 ignition cycles, so as to always guarantee efficient
performance and optimal operation. Please proceed as follows:
1
3
Use the dedicated front heat exchanger cleaning hook to lift the rod and move it backwards and forwards to clean the air heat exchanger of
The ash tray on AURA 100, AURA 120, REA 100, OMEGA and OMEGA PLUS can be inspected by opening the bottom front panel and unscrewing
Remove the flame arrester as shown in the diagram
4
combustion residues
Empty the ash drawer
the two underlying hand wheels.
Remove the ring covering the brazier and remove the combustion residues
2
2
(fig. 1 and
(fig.
3).
(fig.
4).
22
1
2).
5
(fig.
5).
ENGLISH

Publicité

loading