CS.A80.IST-1 / Rev 1.0
INITIAL START-UP
First start-up
Perform the following operations:
-
Connect the appliance to the electrical system by using the provided cable;
-
Set the "power ON/OFF switch" on the rear side of the appliance to "( "׀on);
-
Fill the pellet tank; for the first ever ignition, to avoid wasting the time required for filling the entire screw feed channel (this should be done
every time the appliance runs out of pellets), we recommend you follow the instructions in the "MENU 06 – INITIAL LOAD";
-
Switch on the appliance using the "ON/OFF" key on the remote control (key 3) or on the support panel (key 1). See the instructions below.
Warning: before switching on the device make sure that the brazier is clean and there are no pellets inside it; otherwise it is necessary
to empty and/or clean the brazier.
We recommend that you use high quality pellets so as not to impair the operation of the appliance. Damage caused by poor-quality pellets
shall not be covered by the warranty.
Do not pour pellets manually into the brazier.
Ignition cycle
Holding down key 3 (On/Off) on the remote control or key 1 (On/Off) on the support panel, will switch on the appliance.
The ignition cycle can last 20/25 minutes max. and is divided into five steps:
Phase
Display
1°
CHECK UP
2°
PELLET LOADING
3°
FLAME STAND-BY
FLAME STAND-BY /
4°
PELLET LOADING
5°
STABILISATION
At the end of the ignition cycle, the appliance switches to working mode at the power level set in "SET POWER".
If the ignition fails, the display will show the alarm "IGNITION FAILED".
The alarm may also occur if the brazier is dirty; in this case, clean the brazier and re-start.
Warning: during the ignition phase and normal operation of the appliance, maintain the necessary safety distance and do not stand in front
of it.
Working mode
During the normal working phase, by pressing key 1 (Increase), you can set the "SET ROOM" (room temperature). When this temperature is reached,
the appliance enters economy mode operation "MODULATION", as long as all connected thermostats and temperature sensors are satisfied
also "Connection to the room thermostat or an additional room temperature
-
With "Menu 01-STAND-BY" enabled, the appliance will automatically switch off, switching to "OK ST-BY" status after the time set in Pr44
setting: 10
minutes); once the switching off phase is complete, the appliance will automatically switch back on if the room temperature falls below
the temperature differential set in Pr43
-
With "Menu 01-STAND-BY" disabled, the appliance will switch to MODULATION mode once the set room temperature has been reached and it
will not automatically switch off.
If the above condition occurs when the switch-off cycle is not yet completed, please wait until the cycle is complete.
The cleaning cycle of the brazier (displayed under "BRAZIER CLEANING") is done at predetermined time intervals for an established period
"PCB
parameters").
Meaning
Brazier cleaning cycle
Pre-loading of pellets into the brazier (continuous loading of pellets) to sufficiently fill the
brazier to allow for ignition
Wait before flame ignition after pre-loading (pellet loading suspended)
Loading of pellets into brazier (intermittent pellet loading)
Flame stabilisation, allowing uniform ignition of all pellets unburnt during the previous
stages.
(factory setting: 1°C)
i.e. Room temperature < ("SET ROOM" – Pr43).
sensor").
18
ENGLISH
Duration
Approx. 30 seconds
Approx. 4 minutes
Approx. 4 minutes
Cannot be
determined
Approx. 8 minutes
(See
(factory
(see