A
A. Rigid copper pipe or flexible pipe of
stainless steel
If the pilot lights turn on after
connecting the hob to the
mains, turn on and off the
control knob and wait until
the residual heat indicator
goes out.

3.6 Connection cable

To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H03V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connected
to the network phase.
L
N
3.7 Assembly
1.
2.
3.
min. 100 mm
min. 55 mm
30 mm
+
2
0
4.
min. 650 mm
+
2
830 mm
0