Common faults
The screen wiper basket does not
rotate during operation
The juicing bowl shakes slightly when
the machine is turned on
The safety lid cannot be opened after
juicing
RECYCLING
Environment protection first!
Your appliance contains valuable materials which can be recovered or recycled.
Leave it at a local civic waste collection point.
End-of-life electrical and electronic products:
Your appliance is designed to operate for many years. However, the day you plan to replace it,
do not throw it away with normal household rubbish or in a landfill but take it to a suitable
collection point provided by your local authority (or to a recycling center if applicable).
Environnemental protection first!
Your appliance contains numerous materials that can be recovered or recycled.
Take it to a collection point for processing.
70
Handling method
Check if the gear (L) at the base of the juice bowl
has not deteriorated, if so contact your customer
service
Slight shaking of the juicing bowl during
operation is normal.
There could be too much residual pulp in the
machine. Turn the lever (F) in open position,
press the reverse button and allow the machine to
run in reverse mode for 5 seconds.
If you are unable to resolve the problem after
trying the above, get in touch with our customer
service.