Equipotential
Connection with male thread
bonding
with washers and nut.
Accessories not included (except with offshore version).
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Vented
Max. nominal air flow in vented mode
Max. permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Alternative connection: Ducted air intake (from outside
building)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm (35 ½") long and secured using two screws.
Fittings
Without base
(supplied)
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
On concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
Machine depth
Unit height
Casing width
Casing depth
Minimum width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Min. wall gap (to rear edge of lid)
Net weight
Dynamic floor load, max.
Average heat dissipation
(depends on ambient room temperature and selected
program)
Noise level
Sound pressure level
(measured at a distance of 1 m from the machine and at a
height of 1.6 m).
Installation should only be carried out by authorized fitters in accordance with valid regulations!
Follow installation instructions when installing machine! All rights reserved.
Installation plan: PT 8807 EL (electric)
Date: 01.2015
Unobstructed air intake into room recommended (corre-
sponding to 3 times the vent cross-section of machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
3/8 x 1 3/8"
10 × 35 mm
10 M
647 cfm
1100 m³/h
0.04 psi
300 Pa
5 15/16"
150 mm
5 15/16"
150 mm
176°F
80°C
83 in²
531 cm²
6 5/16"
161 mm
6 5/16"
160 mm
¼ x 1 9/16"
6 × 40 mm
3/8 x 2"
10 × 50 mm
¼ x 1 9/16"
6 × 40 mm
3/8 x 2"
10 × 50 mm
47 ½"
1206 mm
54 ½"
1384 mm
64 9/16"
1640 mm
47 ¼"
1200 mm
50 3/8"
1279 mm
48"
1220 mm
70 7/8"
1800 mm
19 11/16"
500 mm
631 lb
286 kg
3394 N
3394 N
3344 BTU/h
0,98 kW
73.6 dB (A)
73.6 dB (A)
62 dB (A)
62 dB (A)