TB 18
FAULTS
Any operation faults will be displayed after 90 seconds and will be presented on the display with the
following codes:
1
The thermostat has short-circuited or is not correctly connected to the control unit:
2
The compressor is blocked:
3
The ventilator is sending the control unit a value which exceeds 0.6A:
4
The cooling system holds too much gas and the compressor is not able to operate
at the minimum number of revolutions/rpm:
5
The ambient temperature is too high:
6
Insufficient voltage (Voltage below the cut-out value):
7
No communication between the display and control unit, a scrolling horizontal
line appears on the DISPLAY for a few seconds, the refrigerator turns itself off.
HELPFUL ADVICE
Use the product in ECO mode in the following cases:
- when the product is used as a refrigerator and, particularly, where the ambient temperature is not high;
- When the vessel motor is off
REPLENISHMENT
Avoid placing hot food in the refrigerator. Place the products so that they do not knock against each other
or break when the vehicle is in motion.
Ensure that the lid is always firmly on and reduce the time it is left open to the minimum possible.
DEFROSTING
Defrosting must be carried out where the layer of ice is greater than 4 mm thick.
This operation must be performed with the refrigerator off.
Do not remove the layer of ice using sharp or cutting utensils.
Wait until the defrost process has completely finished before switching the refrigerator back on.
MAINTENANCE
Caution
Before carrying out any maintenance operations on the refrigerator, disconnect the power cable
from the
plug..
CLEANING
Regularly clean the inside of the refrigerator using baking soda dissolved in warm water.
Do not, in any case, use abrasive products, detergents or soaps; after washing, rinse with clean water and
carefully dry.
Where the refrigerator is not being used, thoroughly clean and dry the inside in order to avoid the formation
of mould or foul odours.