INSTALLATION | Données ErP
17. Données ErP
AIR 11 C11B
Model:
Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Temperature application:
Climate conditions:
Item
Rated heat output (*)
Declared capacity for heating for part load at indoor temperature 20
°C and outdoor temperature T
T
= -7 °C
j
T
= +2 °C
j
T
= +7 °C
j
T
= +12 °C
j
T
=
bivalent temperature
j
operation limit tempe-
T
=
j
rature
For air-to-water heat pumps:
T
= -15 °C
(if TOL < - 20 ºC)
j
Bivalent temperature
Power input „compressor off"
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
indoors
Sound power level
outdoors
Annual energy consumption
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Contact details:
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heatingPde-
signh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
BIA-AIR M2 M4-FR11 | www.ochsner.com
Symbol
Value
Praded
9
j
Pdh
7.2
Pdh
8.7
Pdh
9.9
Pdh
11.3
Pdh
7.3
Pdh
6.8
Pdh
6.4
T
-6
biv
0
P
20
OFF
P
20
TO
P
20
SB
P
0
CK
fixed
44.5
L
WA
50.4
Q
5412
HE
Q
elec
AIR 11
yes
no
no
no
no
no
medium
average
Unit
Item
Seasonal space heating energy effi-
kW
ciency
Declared coefficient of performance or primary energy ratio for part
load at indoor temperature 20 °C and outdoor temperature T
kW
T
= -7 °C
j
kW
T
= +2 °C
j
kW
T
= +7 °C
j
kW
T
= +12 °C
j
kW
T
=
bivalent temperature
j
operation limit tempe-
kW
T
=
j
rature
For air-to-water heat pumps:For air-
to-water heat pumps:
kW
T
= -15 °C
(if TOL < - 20 ºC)
j
For air-to-water heat pumps:
°C
Operation limit temperature
Heating water operating limit
W
temperature
Supplementary heater
kW
Rated heat output (*)
kW
kW
Type of energy input
kW
For air-to-water heat pumps:
Rated air flow rate, outdoors
dB
For water-/brine-to-water heat pumps:
Rated brine or water flow rate, out-
kWh
door heat exchanger
Water heating energy effi ciency
kWh
Daily fuel consumption
OCHSNER Wärmepumpen GmbH, Ochsner-Straße 1, A-3350 Haag
Symbol
Value
Unit
η
129
%
s
j
COPd
2.60
COPd
3.32
COPd
3.81
COPd
4.44
COPd
2.68
COPd
2.38
COPd
2.08
TOL
-15
°C
WTOL
65
°C
Psup
1.83
kW
electricity
3
5700
m
/h
m
3
/h
η
%
wh
Q
kWh
fuel
75