Electrical data input
Mains voltage
Mains frequency
Mains current
Efficiency
Effective power
Power consumption (standby)
Protection class
EMC emission
Electrical data output
Nominal output voltage
Output voltage range
Output current
Battery return current
Mechanical data
Cooling
Dimensions (l x w x h)
Weight (without cable)
AC Power cable length
DC charging cable length
Environmental conditions
Operating temperature
Storage temperature
Climate class
Ingress protection
Standards
GB
TECHNICAL INFORMATION
100 ~ 240 V AC
50/60 Hz
max. 7. 1 A eff.
max. 94 %
max. 800 W
max. 1.7 W
I
Class A
12 V DC / 6 cells
2 V – 14.7 V DC
50 A at 14,4 V DC
< 1 mA
Convection
280 x 175 x 85 mm
3.8 kg
5 m
2,5 m
-20°C - +60°C
-40°C - +85°C
B
Horizontal position IP5K3
EN 60335-1, EN 60335-2-29, EN 61000-6-2 (EN 61000-4-2,
EN 61000-4-3, EN 61000-4-4) (EN 61000-4-5, EN 61000-4-6,
EN 61000-4-11), EN 55011, EN 62233