Télécharger Imprimer la page

weinor BiSens SW-230V Instructions De Montage page 11

Publicité

Les langues disponibles

Les langues disponibles

Setting the threshold values
On the underside of the BiSens SW-230V you will find multi-way
switches for setting the threshold values for wind and light; these
can be adjusted using a small screwdriver.
OFF
→ light function is switched off
Step 1
→ extend in low light
Light
Step 2-14
→ interim steps
Step 7
→ Factory settings
Step 15
→ Extend at lots of light
Function
→ switching mode
Step 1
→ retract at low wind
Wind
Step 2-10
→ interim steps
Step 4
→ Factory settings
Step 11
→ retract at strong of wing
Checking the light function (test mode)
Condition: The blind is retracted.
The delay times are shortened in the test mode. You can then test
the travel movement of your system when the light threshold is
passed.
1. Press the UP button (wind symbol) for at least 3 seconds until
the green LED flashes.
The test mode stays active for 5 minutes but the LED goes out.
Injury risk from extending the awning or running
down the roller shutter/venetian blind
The test mode is active for 5 minutes. This time cannot
be reduced.
Warning!
Keep away from the operating range of the system.
2. Shine a torch (not an LED lamp) on the light sensor.
The set light target value is exceeded:
→ The blind moves out/down after 5 seconds.
→ Yellow LED flashes.
The set light threshold is undercut:
→ The blind moves in/up after 15 seconds.
→ Yellow LED no longer flashes.
You can repeat the operation as often as you want within 5 min-
utes.
In "normal" operation, the LED flashes every 5 seconds when the
threshold value is reached and passed.
Check the wind function (test mode)
Condition: The blind is retracted.
The delay times are shortened in the test mode. You can then test
the travel movement of your system when the light threshold is
passed.
During the test phase the set wind value is automatically set to the
lowest value and re-set once the test phase (5 minutes) is over.
1. Press the UP button (wind symbol) for at least 3 seconds until
the Transmit LED flashes.
The test mode stays active for 5 minutes but the LED goes out.
Injury risk from extending the awning or running
down the roller shutter/venetian blind
The test mode is active for 5 minutes. This time
cannot be shortened. Keep away from the operating
Warning!
range of the system.
All manuals and user guides at all-guides.com
2. Use the hand-held transmitter to bring the blind to the centre
position
3. Turn the wind vane.
The blind travels in/up immediately.
Set wind value is exceeded/undercut → red LED flashes.
You can repeat the operation as often as you want within 5 min-
utes.
No wind block is active in test mode.
Note: In normal operation, the LED flashes every 5 seconds
In normal operation, the LEDs flash every 5 seconds when the
threshold value is reached and passed.
Deleting programmed BiSens SW-230V
The wind multi-way switch may not be switched to "Function".
Push the UP
and DOWN
buttons at
once
The BiSens SW-230 V is deleted from the receiver.
Mounting options
Warning!
Note:
Wall bracket
The BiSens SW-230V can be fastened to the upper side of the roof
or to the façade using the tilting wall bracket.
The wall bracket can be swivelled between -5° and 180°. Secure
the required position once it has been set (see screw a).
Wall bracket
hinged at 180°
when the threshold value is reached and passed.
At least 3 s.
Function
Off
4
5
Risk of injury from the awning extending and
retracting or the blind being lowered
Winds blowing up or down façades can destroy the
equipment.
The BiSens SW-230 V is not able to recognise these.
Please pay attention to this advice when choosing
the mounting position.
Before installing the unit at the required position, check
the proper function of the BiSens SW-230V and the
receiver. The BiSens SW-230V must not be mounted
under projecting structures.
a
Mast and corner mounting
Optional accessory
(Article No. 118513-0000)
Note: The adapter plate supplied must
be used when fixing the mast and
corner bracket.
Green LED
(send) flashes
briefly.
Wall bracket
hinged at 90°
EN | 3

Publicité