MAINTAINING THE ELECTRONIC
CROSSOVER
IGNITION SYSTEM
®
The igniter module supplies power to the electronic
Crossover
®
ignition system and the side burner with
one igniter button. Whether you are performing routine
maintenance or a troubleshooting check on the ignition
system, read the following to keep your ignition system
working properly.
If the electronic Crossover
®
ignition system fails to ignite,
you'll need to pinpoint where the problem is occurring:
with the gas flow or with the electronic ignition system.
Begin by attempting to match light your burners. Refer
to "MAIN BURNER IGNITION - Lighting with a Match."
If match lighting is successful, the problem lies in the
ignition system.
•
Verify that the AA battery (alkaline only) is in good
condition and is installed correctly (1). Some batteries
have a plastic protective wrap around them. This
plastic must be removed before installing battery. Do
not confuse this plastic with the battery label.
•
Make sure the igniter wires are properly attached to
the igniter module. Refer to the "IGNITER MODULE
WIRE GUIDE" chart on this page.
•
Make sure the ceramic igniter assembly is fully
inserted into burner tube igniter channel (2). If properly
positioned, you will hear a snap (3).
•
Make sure the electronic igniter button is working by
listening for clicking and looking for sparks at burner.
If the electronic Crossover
ignition system still fails
®
to ignite, contact the Customer Service Representative
in your area using the contact information on our web
site. Log onto www.weber.com
.
®
30
WWW.WEBER.COM
®
ROUTINE MAINTENANCE
IGNITER MODULE WIRE CHART (E220 / E320 / SP320)
4
3
6
5
2
1
BURNER 1
Black Terminal (1)
Yellow Terminal (2)
2
3
1
SIDE BURNER
Blue Terminal (3)
Green Terminal (4)
2
1
4
3
5
6
IGNITER BUTTON
Black Terminal (5)
Black Terminal (6)