Télécharger Imprimer la page

GreenWorks TRC40678 Manuel D'utilisation page 34

Publicité

Les langues disponibles

Les langues disponibles

EN
Error
Description
Code
M26
CAN timeout error - drive
M31
Blade switch signal abnormal
M33
Grass-collecting switch signal
abnormal
PMU10
Open circuit in battery pack in
PMU
PMU1
Overcurrent-Level1
PMU2
Overtemperature-Level1
PMU3
Overtemperature in feedback
module-Level1
PMU32
Overcurrent-Level2
PMU33
Hardware overcurrent
PMU34
Hardware overcurrent
PMU35
Overtemperature-Level2
PMU36
Undervoltage
PMU37
Overvoltage
PMU38
Power supply output failure
PMU39
Overtemperature in feedback
module-Level2
PMU40
Power resistor overtemperature
in feedback module
PMU41
No battery pack available
PMU42
Battery pack low temperature
PMU43
Battery pack communication er-
ror
PMU44
Microcontroller self-test error
PMU45
Battery pack high temperature
PMU46
Power circuit error
PMU47
Pre-charge error
PMU48
Pre-charge hardware error
PMU49
Negative MOS temperature
sensing error
PMU50
Feedback MOS temperature
sensing error
PMU51
Driver voltage error in feedback
module
PMU52
Current sensor error
English
Solution
Communication error with the drive controller. Restart the power sup-
ply.
Check that the Blade switch is connected properly, and then return
the switch to its initial position.
Check that the Grass-collecting switch is connected properly.
Unconnected battery pack in battery compartment; product perform-
ance may be affected.
The PMU load is too high. The error will automatically resolve itself
when the load drops.
The PMU temperature is too high. The error will automatically resolve
itself when the temperature drops.
The error will automatically resolve itself when the temperature
drops.
The PMU load is too high. Restart the power supply.
The PMU load is too high. Restart the power supply.
Restart the power supply.
The PMU temperature is too high. Wait until the temperature drops,
then restart the power supply.
The voltage is too low. Charge the battery pack and try again.
The voltage is too high. Restart the power supply.
Restart the power supply.
Wait until the temperature drops, then restart the power supply.
Wait until the temperature drops, then restart the power supply.
Check that you are using the correct battery pack, and then restart
the power supply.
Ensure that the ambient temperature is above 0 degrees Celsius.
Replace the battery pack.
Restart the power supply and contact your distributor for a solution.
Wait until the temperature drops, then restart the power supply.
Contact your distributor for a solution.
Restart the power supply and contact your distributor for a solution.
Contact your distributor for a solution.
Contact your distributor for a solution.
Contact your distributor for a solution.
Contact your distributor for a solution.
Contact your distributor for a solution.
34

Publicité

loading

Ce manuel est également adapté pour:

Crt308Crt306Trb456Ztb456