© MOSA
1.1-02/03
When the TCM 22-40 is used, it is not possible to connect the E.A.S automatic intervention unit.
The selector LOCAL START/REMOTE START (I6) of the generating set must be switched on REMOTE
START.
USE OF THE REMOTE CONTROL
TCM 22
The coupling of the TCM 22 with the generating set,
ready for remot starting, permits to work far from
the set itself.
The remote control is connected to the front plate,
and/or rear plate, with a multiple connector.
The TCM 22 assures the following fonctions:
- starting (starting key Q1)
- acceleration (selector 16)
- stop (starting key Q1)
- indication of oil low pressure (warning light O1)
To stop the set, move the accelerator lever (16) to
the minimum position, them turn the key to "OFF"
position.
USE OF THE REMOTE CONTROL TCM 40
The coupling of the TCM 40 with the generating set,
ready for remot starting, permits to work far from
the set itself.
The remote control is connected to the front plate,
and/or rear plate, with a multiple connector.
The TCM 40 assures the following fonctions:
- Preheat (starting key Q1). Use only for the models
that need such function:
- starting (starting key Q1)
- stop (starting key Q1)
- indication of oil low pressure (warning light O1)
To stop the set turn the key to the position."OFF".
TCM 22 - 40 REMOTE CONTROL
!
MAKE SURE
M
38.5.
1
INSERT AND
HOOK UP
INSERT AND
HOOK UP