Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for use (rev 05/18)
NOTE:
 High translucency zirconia are very sensitives. To avoid and prevent crossed discoloration with
other zirconia brand or type, user must do regularly clean program (N° 40).
 If liquid shades are used with staining technic, prosthetics units must be dry and preheated with
an infra red lamp or into an oven to prevent pollution into the eON Sinter, in following zirconia
and shades manufacturer recommandations.
 White clusters can appear on the rods (heating elements) when differents brands or types of
zirconia are used. In this case user must clean mufle and rods with a special zirconia cleaner like
Nacera Clean (registered brand) with clean program N° 40.

6.6.2. Exemple of programs

Next, and as an example, four sintering curves:
Sintering curve No. 1
(1 to 3 unit or bridges)
Stage
1
C1: 0
2
C2: 300
3
C3: 1000
4
C4: 1480
5
C5: 1480
6
C6: 800
Sintering curve No. 3
(6 to 8 unit or bridges)
Stage
1
C1: 0
2
C2: 300
3
C3: 1000
4
C4: 1480
5
C5: 1480
6
C6: 800
UGIN DENTAIRE
Temperature
Time
(°C)
(minutes)
T1: 30
T2: 30
T3: 120
T4: 60
T5: 60
T6: -121
Temperature
Time
(°C)
(minutes)
T1: 30
T2: 60
T3: 240
T4: 90
T5: 90
T6: -121
Sintering curve No. 2
(4 to 5 unit or bridges)
Temperature
Stage
(°C)
1
C1: 0
2
C2: 300
3
C3: 1000
4
C4: 1480
5
C5: 1480
6
C6: 800
Sintering curve No. 4
(9 and above unit or bridges)
Temperature
Stage
(°C)
1
C1: 0
2
C2: 300
3
C3: 1000
4
C4: 1480
5
C5: 1480
6
C6: 800
e.ON SINTER
Time
(minutes)
T1: 30
T2: 60
T3: 180
T4: 90
T5: 60
T6: -121
Time
(minutes)
T1: 30
T2: 90
T3: 360
T4: 90
T5: 90
T6: -121
38

Publicité

Table des Matières
loading

Table des Matières