Télécharger Imprimer la page

GAPOSA QC100U Mode D'emploi page 14

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8. EMERGENCY MODE WITH FAULTY BAR
This mode allows the movement of the motor with dead-man control also in case the optoelectronic
bar is active or faulty.
Mode description:
• The mode becomes operational after about 30 seconds from the coast activation (the count is reset if
the bar returns to visibility)
• The mode allows the movement of the motor in opening and closing in dead-man mode regardless of
the position of the dip 2.
• The movement of the motor during this mode is automatically stopped after 5 seconds. The
movement can be resumed by pressing the command again.
Mode activation:
1. Put dip 6 in ON
2. Move dip 3 at least 3 times from ON to OFF (between two OFF-ON consecutive steps shall not be
more than 2 seconds or the movements count is reset)
3. If the change is activated, the red and green LEDs will flash quickly for about 4 seconds
4. Put dip 6 back in OFF
Once the mode activated, it will be actually present only in case dip 3 and 4 are in ON (safety active also
in opening and optoelectronic bar active). Otherwise, the mode is not operational even if enabled.
Mode disabling:
The mode can be disabled exclusively by the reset procedure (see procedure).
9. RESET
Through the reset procedure, the programming of pause time and of the stroke are reset to default
conditions (working time of 30 seconds, automatic closing disabled). The "Emergency mode with faulty
bar" is also turned off. During the reset procedure, all controls are inhibited.
To reset the control unit, you must:
1. Place all DIP in OFF
2. Place DIP 5 and 6 in ON
3. The green LED will switch off while the red one will start flashing rapidly. After the reset, the red
LED switches off while the green LED will start making three quick flashes every 3 seconds.
4. Place DIP 5 and 6 in OFF. The green LED will remain ON and steady and the reset procedure is
completed.
5. You can now reposition the DIP according to the desired functions.
14

Publicité

loading

Ce manuel est également adapté pour:

Qc101u