Manual BVS 22 ATEX E 009 X
3.3
Enclosure ingress protection
Degree of protection IP 66 or IP 68
3.4
Voltages and frequencies
Tension
Frequency
Power
Ambient temperature –20 to 60 °C
3.6
Type code
The explosionproof tube lights type TL**de have
the following type code:
TL 60 de 22 1500 K
K... with contact stripes (IIC)
max. length [mm]
2200 mm*
nominal power [Watt]
polycarbonate
diameter 60 mm
diameter 100 mm
diameter 100S with flange socket
borosilicate glass (Duran)
diameter 55 mm
* The maximum permissible length of the flameproof
inner tube is 2100 mm
4.
Installation
For installation and operation, the rules of
generally accepted engineering practice, the
provisions of IEC 60079-14 'Electrical instal-
lations design, selection and erection', natio-
nal regulations and the instructions set out
in this Manual must be observed.
4.1
Electrostatics
4.1.1 Lamps with contact strips (Group IIC
with "K" in the type code)
The TL**de tube lights with contact strips are fit-
ted with a 3-pole conductor. In order to prevent
hazardous charges, the earth wire must be con-
Edition August 2022
Copyright
12-50 V DC / AC
100-265 V DC/ AC
50/60 Hz ±10%
max. 36 W/m with
regard to the LED tube
thuba Ltd., CH-4002 Basel
Switzerland
7