Manual BVS 22 ATEX E 009 X
Explosionproof tube lights
type TL**de
in protection types
flameproof enclosure / increased safety
Ex db eb IIC/IIB T5 Gb
protection by enclosure
Ex tb IIIC T95°C Db
Target group
Experienced qualified electricians in accordance
with the occupational health and safety decree
and trained persons.
Contents:
1.
Safety rules
2.
Conformity with standards
3.
Technical data
4.
Installation
5.
Inspection, Maintenance and Repair
6.
Disposal
1.
Safety Rules
The explosionproof tube lights type TL**de are
used in hazardous areas designated as Zones 1
and 2 as per IEC 60079-10-1 or Zones 21 and
22 as per IEC 60079-10-2.
Operate the tube lights type TL**de only for
their intended duty and when in an undama-
ged and clean condition, and only where the
enclosure material is capable of withstanding
the ambient conditions.
In the event of incorrect assembly, the degree of
protection IP 66 or IP 68 (2.5 m head of water
above test specimen with a test duration of 30
minutes) as per IEC 60529 will no longer be
assured.
TL**de tube lights without contact strips (no
K in the type code) may only be installed in
systems where there is no charging during
operation.
The flameproof LED tubes may only be repla-
ced outside the hazardous area
Edition August 2022
Copyright
thuba Ltd., CH-4002 Basel
Switzerland
3