Installation site selection - Indoor unit
AVOID
• Direct sunlight.
• Nearby heat sources that may affect unit performance.
• Areas where leakage of flammable gas may be expected.
• Locations where large amounts of oil mist may occur (such as
in kitchen or near factory equipment) because oil contamination
can cause operation problems and may deform plastic surfaces
and parts of the unit.
• Unsteady locations that will cause noise or possible water
leakage.
• Locations where the remote control unit will be splashed with
water or affected by dampness or humidity.
• To make holes in areas where electrical wiring or conduits are
located.
DO
• Select an appropriate position from which every corner of the
room can be uniformily cooled.
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
G
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene
(min. thickness 8mm).
MODEL
OUTER DIAMETER
UR9X - UR12X
UR18X
UR22X
G
PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
G
Anti-freeze oil for flare connections (about 30g.).
G
Electric wire: use insulated copper wires of size and length as shown in the table "ELECTRICAL DATA" and at paragraph "SYSTEM WIRING
DIAGRAMS".
ELECTRICAL DATA
Power supply wiring length
MODEL
(A) m
CR9X
140
CR12X
CR/CLR18X
CR22X
TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
MAX. ALLOWABLE
MODEL
TUBING LENGTH AT
UR9X
UR12X
UR18X - 22X
* For every meter of tube more than standard lenght at shipment, add refrigerant as shown in the table. No additional charge
of compressor oil is necessary.
NARROW TUBE
MIN. THICKNESS
6,35 mm
6,35 mm
6,35 mm
LENGTH, WIRE SIZE AND DELAYED FUSE
Power line length
2
mm
80
2
3,5
50
2
90
3,5
22
2,5
16
2,5
LIMIT OF TUBING
SHIPMENT
(m)
7,5
7,5
7,5
• Select a sufficiently strong location to support the weight of the
unit.
• Select a location where tubing and drain hose have the shortest
run to the outside.
• Allow access for operation and maintenance as well as
unrestricted air flow around the unit.
Installation site selection - Outdoor unit
AVOID
• Heat sources, exhaust fans.
• Direct sunlight.
• Damp, humid or uneven locations.
• To make holes in areas where electrical wiring or conduits are
located.
DO
• Choose places as cool as possible and well ventilated.
• use lug bolts or equal to bolt down the unit, reducing vibration
and noise.
OUTER DIAMETER
0,8 mm
9,52 mm
0,8 mm
12,7 mm
0,8 mm
15,88 mm
Control line length
2
mm
(B) m
80
2
140
3,5
50
2
90
3,5
30
2,5
30
2,5
LIMIT OF ELEVATION
LENGTH
DIFFERENCE
(m)
15
20
30
3
LARGE TUBE
MIN. THICKNESS
0,8 mm
0,8 mm
1 mm
2
Delayed fuse
mm
(C) m
160
0,75
160
0,75
30
2,5
30
2,5
REQUIRED AMOUNT OF
ADDITIOONAL
H
REFRIGERANT
(m)
(g / m)*
7
7
7
EG
10 A
10 A
20 A
20 A
15
25
25
(go on page 4)