Indoor Unit
Air Intake
Air Discharge
Air Discharge
Return Air
Air Discharge Nozzle
The outdoor unit must be installed such that there is no short
circuit of the hot discharge air or obstruction to the smooth
air flow. Please follow the installation clearance shown
below. Select the coolest possible place where intake air
temperature is not greater than the outside air temperature
(maximum 45°C).
Installation Clearance
Dimension
A
Minimum
300
Distance (mm)
Note : If there is any obstacle higher than 2m, or if there is
any obstruction at the upper part of the unit, please allow
more space than the figure indicated in the above table.
The indoor unit must be installed in such a way so as to
prevent short circuit of the cool discharged air with the hot
return air. Please follow the installation clearance shown in
the figure. Do not place the indoor unit where there could
be direct sunlight shining on it. Also, this location must be
suitable for piping and drainage, and be away from doors
or windows.
50.0 mm
Air Flow
Direction
Maintenance &
Servicing Space
Plate Mounting
Installation
Ø 65.0 mm Hole in
All manuals and user guides at all-guides.com
INSTALLATION DIAGRAM
Air Filter
Grille
Louver
Indicator
Light
Grille
Signal Receiver
INSTALLATION OF OUTDOOR UNIT
B
C
D
1000
300
500
INSTALLATION OF INDOOR UNIT
50.0 mm
Screw position in the
wall
the wall
Front Frame
Back Housing
Main Switch
ON/OFF Switch
Drain Hose
Refrigerant Piping
Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with
4 suitable screws.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see figure).
Ø 65.0 mm Hole in the wall
Hole With Cone Drill
Indoor Side
Routing Of Piping
Remove the screw holding the front panel.
Piping Routing
1-3
Outdoor Unit
Screw position in the wall
Centre Line
Outdoor Side