Télécharger Imprimer la page

Firman W03383 Manuel Du Propriétaire page 27

Masquer les pouces Voir aussi pour W03383:

Publicité

Les langues disponibles

Les langues disponibles

ENGINE MAINTENANCE
To prevent accidental starting, remove and
ground spark plug wire before performing any
service.
Change Engine Oil
Change engine oil every 100 hours.
(for a new engine, change oil after 25 hours.)
If you are using your generator under extremely
dirty or dusty conditions, or in extremely hot
weather, change the oil more often.
CAUTION
Avoid prolonged or repeated skin contact with
used motor oil.
Used motor oil has been shown to cause skin
cancer in certain laboratory animals.
Thoroughly wash exposed areas with soap
and water.
(a) Loosen the cover screws and remove the
maintenance cover.
(b) Pop up the rubber plug from below yellow
draining bolt.
(c) Remove yellow drain bolt.
(d) Tilt the generator on its side and allow the oil to
drain completely.
(e) Replace yellow drain bolt.
Fill the engine with oil until it reaches the HIGH
(f)
(H) level on the oil filler cap
English
. DO NOT OVERFILL.
Page 24
Use fresh and high quality lubricating oil to the
specified quantity.
If contaminated or deteriorated oil is used or
the quantity of the engine oil is not sufficient,
the engine damage will result and its life will be
greatly shortened.
Air Filter Maintenance
Maintaining an air filter in proper condition is
very important. Dirt induced through improperly
installed, improperly serviced, or inadequate
elements damages and wears out engines.
Always keep the element clean.
(a) Remove the air cleaner cover and locate the
air filter plastic cover.
(b) Remove the foam element.
Foam Element
(
c) After wetting the element by clean engine
oil squeeze it tight by hand.
(d) Put the element in the case and install it
securely.
(e) Reattach the air filter cover.
(f) Reinstall the air cleaner cover and tighten the
cover screw securely.
Air Cleaner
Customer Service: 1-844-FIRMAN1

Publicité

loading