12

12 Device Information

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
3.6
Brine throughput with an internal pressure
differential (heat source) of
3.7
Refrigerant; total filling weight
3.8
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.
E-8
°C
°C
at B0 / W35
K
1
at B-5 / W55
kW / ---
1
at B0 / W45
kW / ---
1
at B0 / W50
kW / ---
1
at B0 / W35
kW / ---
dB(A)
m³/h / Pa
type / kg
type / litres
2
H x W x L mm
Inch
Inch
kg
V / A
1
B0 W35
kW
A
A / ---
4
SI 5ME
SI 7ME
SI 9ME
IP 20
IP 20
IP 20
Indoors
Indoors
Indoors
Up to 58
Up to 58
Up to 58
-5 to +25
-5 to +25
-5 to +25
Mono-ethyl-
Mono-ethyl-
Mono-ethyl-
ene glycol
ene glycol
ene glycol
25%
25%
25%
9.6
5.0
9.1
5.0
10.5
4.0 /
5.4 /
7.6 /
2.0
2.1
2.1
4.6 /
5.7 /
2.7
2.7
4.8 /
6.2 /
8.8 /
2.7
2.7
2.7
5.0 /
4.9 /
6.5 /
6.3 /
9.3 /
4.0
3.8
3.9
3.7
4.0
54
55
56
0.45 /
0.85 /
0.6 /
1.1 /
0.75 /
1900
6500
3300
10000
2300
1.2 /
1.2 /
1.7 /
1.7 /
2.3 /
16000
16000
29500
29500
25000
R407C / 1.2
R407C / 1.4
R407C / 1.7
Polyolester
Polyolester
Polyolester
(POE) / 1.0
(POE) / 1.0
(POE) / 1.1
805 × 650 ×
805 × 650 ×
805 × 650 ×
462
462
462
G 1¼" exter-
G 1¼" exter-
G 1¼" exter-
nal
nal
nal
G 1¼" exter-
G 1¼" exter-
G 1¼" exter-
nal
nal
nal
109
111
118
230 / 16
230 / 16
230 / 20
1.26
1.30
1.68
1.70
2.30
24
26
38
6.8 /
7.1 /
9.1 /
9.3 /
12.6 /
0.8
0.8
0.8
0.8
0.8
3
3
3
No
No
No
1
1
1
Internal
Internal
Internal
SI 11ME
SI 14ME
IP 20
IP 20
Indoors
Indoors
Up to 58
Up to 58
-5 to +25
-5 to +25
Mono-ethyl-
Mono-ethyl-
ene glycol
ene glycol
25%
25%
5.0
9.5
5.0
9.6
5.0
9.4 /
12.3 /
2.0
2.1
8.5 /
10.0 /
14.7 /
2.8
2.9
2.9
10.5 /
14.2 /
2.6
2.8
8.9 /
11.0 /
10.8 /
15.0 /
14.8 /
3.8
4.0
3.9
4.1
3.9
56
56
1.5 /
1.0 /
1.9 /
1.3 /
2.6 /
9200
4100
15000
4800
19200
2.0 /
3.0 /
2.5 /
3.5 /
3.5 /
20000
24000
18000
20000
20000
R407C / 1.9
R407C / 2.2
Polyolester
Polyolester
(POE) / 1.36
(POE) / 1.90
805 × 650 ×
805 × 650 ×
462
462
G 1¼" exter-
G 1¼" exter-
nal
nal
G 1¼" exter-
G 1¼" exter-
nal
nal
122
130
230 / 25
230 / 32
2.35
2.75
2.77
3.70
3.76
38
50
12.9 /
15.0 /
15.3 /
19.7 /
20.0 /
0.8
0.8
0.8
0.8
0.8
3
3
No
No
1
1
Internal