Special Hazards - WIKA NS100 Mode D'emploi

Masquer les pouces Voir aussi pour NS100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Safety
Required temperature
class
(ignition temperature of
gas or vapour)
T4 (T > 135 °C)
T3 (T > 200 °C)
T2 (T > 300 °C)
T1 (T > 450 °C)
Hazardous dust atmosphere
For dusts, the procedure specified in ISO/IEC 80079-20-2 for determining the
ignition temperature has to be applied. The ignition temperature is determined
separately for dust clouds and dust layers, respectively. For dust layers, the
ignition temperature depends on the dust layer thickness per IEC/EN 60079-14.
Ignition temperature
of dust
Dust cloud: T
cloud
Dust layer: T
layer
The permissible maximum medium temperature must not exceed the lowest
determined value, even in case of a malfunction.

2.4 Special hazards

WARNING!
For hazardous media such as oxygen, acetylene, flammable or
toxic gases or liquids, and refrigeration plants, compressors, etc., in
addition to all standard regulations, the appropriate existing codes or
regulations must also be followed.
For additional important safety instructions see chapter 2.3 "Safety instructions
for pressure gauges per ATEX".
WARNING!
Residual media in dismounted pressure gauges can result in a risk to
persons, the environment and equipment.
Take sufficient precautionary measures.
WIKA operating instructions pressure gauge, model 4 per ATEX
Maximum permissible medium temperature
(in the measuring system)
dry gauges
+105 °C
+160 °C
+200 °C
+200 °C
Maximum permissible medium temperature
(in the measuring system)
< 2/3 T
cloud
< T
− 75 K − (reduction depending on the layer thickness)
layer
liquid-filled gauges
+100 °C
+100 °C
+100 °C
+100 °C
EN
7