INSTALLATION
Connections
Ducted version air exhaust system
When installing the ducted version, connect the hood to the chimney
using either a flexible or rigid pipe ø150 or 120 mm, the choice of which
is left to the installer.
• To install a ø120 mm air exhaust connection, insert the reducer
flange '9' on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not supplied).
• Remove possible charcoal filters.
Recirculation version air outlet
• Cut a hole ø125 mm in any shelf that may be positioned over the
hood.
• Insert the reducer flange '9' on the hood body outlet.
• Connect the flange to the outlet on the shelf over the hood by using
a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps (not supplied).
• Fix the air outlet grid '8' on the recirculation air outlet by using the
2 screws '12e' (2,9 x 9,5) provided.
• Ensure that the activated charcoal filters have been inserted.
EN 11