Alignment
Alignment mode can be used with the laser in
Horizontal Orientation (to slope), or Vertical mode
(to align). The Laser can only slope in the Y Axis.
1. Select the Alignment icon from the main menu.
2. When in Horizonal mode, press the up/down arrow
keys to slope. When in Vertical Orientation, press
the left/right arrow buttons to align. Press and hold
the arrow button to slope/align at a faster rate.
3. Press the OK button to confirm the current slope
selection.
4. After the laser is sloped (in Horizontal Orienta-
tion only), the left and right arrow buttons can
be pressed simultaneously to exit Alignment and
re-level the laser plane.
NOTE: The Laser Locator Indicator LEDs and audible
sounds will function during alignment if the user
wishes to use them to align the laser with the center
of the Remote/Receiver while in Alignment Mode.
The Mask function can be used to turn off the laser in
certain quadrants to prevent interference with other
Remote/Receivers on the jobsite.
1. Select the Mask icon from the main menu and
press the OK button. Four quadrants will appear
on the screen.
2. Press the up, down, left, or right arrow buttons to
select the desired quadrants to be masked. Masks
will be applied in real time to the laser.
3. To unselect a mask, press the arrow button in the
direction needed to unmask.
4. Press the OK button when mask selection is
complete.
NOTE: Up to 3 adjacent quadrants can be selected
at a time. If a fourth or non-adjacent quadrant is
masked, the selected quadrant will become masked.
All other previously masked sections will become
unmasked to resolve the conflict.
1. Press the Sweep button or select the sweep icon
in the main menu.
2. Press the up arrow button to select which degree
of sweep is needed; 0°, 10°, 45°, and 90°. Use the
left and right arrow buttons to rotate the laser beam
counterclockwise or clockwise if needed. Single
Mask
Sweep
press the arrow button to move 1 step, or press
and hold the arrow button to move at a faster rate.
3. Use the down arrow button to snap the sweep
direction to the next quadrant. Press again to
proceed to next quadrant. And so on.
4. Press the OK button to confirm the selection. The
Remote/Receiver will return to the main menu.
Rotational Mode
1. Select the RPM icon from the main menu and
press the OK button. Three RPM options will ap-
pear; 300, 600 (default), and 1200.
NOTE: Slower RPM's are more visible, while faster
RPM's will yield a more continuous looking line that
is better for detection reaction time.
2. Press the up and down arrow buttons to select the
RPM as needed.
3. Press the OK button, and the RPM will change
according to the RPM selected.
Center Lock
Center Lock is only compatible with certain RPM's
and accuracy settings and is not compatible with
Channel Link. Some settings may automatically
change when this function is being used. Press the
OK button to clear any setting change notification of
the Remote/Receiver.
1. Place the paired Remote/Receiver in the desired
location.
NOTE: The Remote/Receiver must be aligned with
the Y axis of the rotary laser. For best results, use
the iron sight on top of the laser to align directly
with the Remote/Receiver sensor.
2. To LOCK, select the Center Lock icon from the
main menu and press the OK button. The laser
will begin to slope in the Y axis searching for the
Remote/Receiver.
3. If the center is found, the Remote/Receiver will
display "Center Locked".
4. Once the center is locked, the laser will continue
to adjust it's slope to remain on the center of the
Remote/Receiver. If the Remote/Receiver is ever
blocked or moved such that the laser beam is no
longer on the sensor, this operation will fail and a
"not found" warning will be displayed.
NOTE: If Center Lock is not found, the Remote/
Receiver will display "not found". Press the OK
button, and the remote/receiver will go to the main
menu, and the laser will start the self-leveling
sequence. Select the Center Lock icon from the
menu, and try steps 1 - 3 again until Center Lock
is found.
5. To UNLOCK, select the Center Lock icon from the
main menu, and press the OK button. Hold the left
arrow and right arrow buttons simultaneously, the
Center Lock Function will be aborted and the laser
will begin the auto-level sequence.
5