3. GENERAL SAFETY INFORMATION
6. All electrical power must be disconnected at the main service box, which must be
locked before connecting, inspecting, cleaning or servicing the heater. This is an im-
portant precaution to prevent serious electric shock.
7. This is heater is not suitable for use in hazardous locations containing explosive
liquids or vapours. This heater has hot or arcing or sparking pads inside. Do not use it
in areas where gasoline, paint or flammable liquids are used or stored.
8. This heater is not suitable for use in corrosive atmospheres such as marine green
houses or chemical storage areas.
9. This heater must be mounted at least 8 feet off the floor. For specific clearances,
please see next page.
Improper installation or failure to follow the procedures outlined in this instruction
manual can result in serious electrical shock.
4. LOCATING HEATER
Install heater away from traffic areas, maintaining clearances stated in figure 2 (below).
The air flow direction should not be restricted (ie. by columns or machinery). The air
flow should wipe exposed walls rather than blowing directly on them. When more than
one heater is used in an area, heaters should be installed so that the air discharge of each
heater supports the air flow of the others, to provide best warm air circulation as shown
in figure 3.
WARNING
Figure 2
4