NiMH charging mode
When charging NiMH batteries, the charger is
switched off using the Delta Peak Method.
Battery status
LED and battery type flash
1
No charging
green at 0.5 sec intervals
2
Charging started
LED constantly lights green
Beeper sounds for 15 sec
3
Battery charged

8. Equalizing Without Charging

1. Use the voltage sensor lead to connect a
lithium battery to the charger via the voltage
sensor connection.
2. Ensure correct polarity and position when
connecting. The black wire of the sensor lead
must be aligned with the arrow mark on the
charger casing.
3. Ensuring correct polarity, now connect the
main power cables of the battery to the con-
nection at the charger (red = +/black = -).
4. Briefly press the Start button.
5. The battery voltage is shown in the display
during the charging process.
6. Briefly press the Start button again to stop the
equalizing process.
The equalizer LEDs indicate the status of the
connected cells.
Constantly flashing or lit LEDs indicate that the
cells are being balanced.
The LEDs only flashing sporadically or off indi-
cate that the battery is balanced and is ready for
use.
Battery status
1
Equalizing phase
LED flashes orange with
2
End of equalizing
number of cells, beeper
Table of contents
Power Peak® A4 EQ-LCD
Status LED
LED lights orange
Status LED
LED flashes orange
at 0.5 sec intervals
sounds for 15 sec
6
14

9. Fault Signalling

A fault is indicated by the status LED flashing
in the corresponding LED flash sequence, (----)
flashing in the LC display and the beeper sound-
ing at 0.5 second intervals.
After eliminating the cause of fault, the fault code
memory is reset by pressing the Start button.
Cause of fault
Input voltage is lower than
1
11 or higher than 15 Volt
Battery connected with
2
reversed polarity
Main power supply cable dis-
3
connected during charging
Sensor lead disconnected
4
during charging
5
Fault in power circuit
10. Specification – Charger
Input:
Number of cells:
Charging current:
Charging power:
Charge termination:
Dimensions:
Protective functions
Polarity reversal protection
- Input side:
- Output side:
11. Specification – Power Supply Unit
(No.8560)
Input:
Charge current
Output:
Dimensions:
Protective functions
- Output side:
# 30 8560
LED
flash sequence
1
2
3
5
6
11...15 V DC /
110-230 V AC
1...4 LiPo cells
4 ... 8 NiMH cells
0.3 ... 3 A
max. 30 W
CC-CV/Delta Peak
120 x 65 x 24 mm
Polarity reversal and
short-circuit protection
110-230 V AC/50 Hz
max. 4 A
12 V DC
111 x 47 x 33 mm
Polarity reversal
protection