Télécharger Imprimer la page

Klein Tools KLE-CL445 Manuel D'utilisation page 8

Multimètre à pince cvc, technologie de mesure à valeur efficace vraie

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
ON/OFF
To power ON the meter, rotate the Function Selector switch
the OFF setting to any measurement setting. To power OFF the meter,
rotate the Function Selector switch
the meter will automatically power OFF after 10 minutes of inactivity. If
the meter automatically powers-OFF while in a measurement setting,
press any button to power the meter ON, or rotate Function Selector
switch to OFF, then power ON the meter. To deactivate the power OFF
functionality press and hold the "SELECT" button
ON from the OFF setting. When auto power OFF is deactivated, the Auto
Power Off icon
SEL / NCV BUTTON (FOR NCV TESTING)
Press and hold the SEL/NCV button
Testing (NCV) mode to test for presence of AC voltage. The NCV
icon and "EF" will be present on the display. Approach the conductor
under test leading with the sensing antenna
voltage, the red NCV light
will sound. Release the SEL/NCV button to exit NCV testing mode.
NOTE: Only voltages of 40V AC or greater will be detected.
BACKLIGHT
Press Backlight/Worklight button
The backlight does not automatically power OFF.
WORKLIGHT
Press and hold Backlight/Worklight button
or OFF the worklight. The worklight does not automatically power OFF.
RANGE
The meter defaults to auto-ranging mode
automatically determines the most appropriate measurement range
for the testing that is being conducted. To manually force the meter
to measure in a different range, use the "RANGE" button
1. Press the "RANGE" button
range (
"RANGE" button
once the desired range is reached.
2. To return to auto-ranging mode, press and hold the "RANGE"
button
for more than two seconds (
7
MAX/MIN
When the "MAX/MIN" button
the Maximum and Minimum values.
1. When measuring, press "MAX/MIN" button
Maximum value (MAX), the Minimum value (MIN). If a new maximum
or minimum occurs, the display updates with that new value.
2. Press "MAX/MIN" button
to normal measuring mode.
DATA HOLD
Press HOLD
9
HOLD
again to release the display to return to live measuring.
9
8
FUNCTION BUTTONS
will not be visible in the display.
13
is deactivated on the LCD). Repeatedly press the
to cycle through the available ranges, stopping
7
8
to hold the measurement on the display. Press
to the OFF setting. By default,
2
12
to enter Non-contact Voltage
will illuminate, audible signals (beeps)
to turn ON or OFF the backlight.
6
6
to manually select measurement
7
is pressed, the meter keeps track of
8
for more than two seconds to return
before powering
12
. In the presence of AC
14
for 2 seconds to turn ON
. This mode
7
is reactivated).
to toggle between the
8
from
2
2
.

Publicité

loading

Ce manuel est également adapté pour:

Cl445