CLEANING THE BREW GROUP.
The Brew Group must be cleaned at least once a week. Before removing the group, remove the coffee
grounds drawer as shown in fi g.1 on page 36.
Wash the Brew Group with lukewarm water.
Lubricate the Brew Group after approximately 500 brewing cycles. The grease for the Brew Group's
lubrication may be purchased in authorized service centres.
WARNING! Do not wash the Brew Group with detergents that can compromise its correct operation.
Do not wash in the dishwasher.
1
Press the PUSH button to remove
the Brew Group.
4
Apply the lubricant evenly on both
side guides.
7
The lever on the rear part of the
group must be in contact with
the group base.
2
Wash the Brew Group and the fi lter
and dry.
5
Make sure the Brew Group is in
rest position; the two references
must match.
8
Insert the washed and dried Brew
Group. DO NOT PRESS THE
"PUSH" BUTTON.
3
Lubricate the Brew Group guides
using the supplied lubricant.
6
Make sure the components are
in the correct position. The hook
shown must be in the correct
position; to check its position,
fi rmly press the "PUSH" button.
9
Insert the coffee grounds drawer.
Close the service door.
37