14 | English
Universal detector
– Concrete operating mode: Cables and water-filled plastic pipes
– Universal operating mode
– Drywall operating mode
– Drywall operating mode: Wooden beams
Accuracy of object centre measurement
Minimum distance between two neighbouring objects
Operating frequency range
Max. transmission power
Max. altitude
Relative air humidity max.
– For detecting objects
– For classifying power cables
Pollution degree according to IEC 61010-1
Measuring tool power supply
– Rechargeable battery (Li-ion)
– Non-rechargeable batteries (alkaline manganese)
Approx. operating time
– Rechargeable battery (Li-ion)
– Non-rechargeable batteries (alkaline manganese)
Weight according to EPTA-Procedure 01:2014
– With rechargeable battery
– With non-rechargeable batteries
Recommended ambient temperature during charging
Permitted ambient temperature during operation
Permitted ambient temperature during storage
Recommended rechargeable batteries
Recommended chargers
A) Depends on operating mode, material and size of the objects, as well as material and condition of the base material
B) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
C) Depends on battery in use
The serial number (13) on the type plate is used to clearly identify your measuring tool.
The accuracy and detection depth of the measuring
u
result may be negatively affected if the condition of
the substrate is unfavorable.
Operation
Protect the measuring tool from moisture and direct
u
sunlight.
Do not expose the measuring tool to any extreme tem-
u
peratures or variations in temperature. In case of
large variations in temperature, leave the measuring
tool to adjust to the ambient temperature before
switching it on. The accuracy of the measuring tool and
the functionality of the display may be compromised if ex-
posed to extreme temperatures or variations in temperat-
ure.
1 609 92A 7KZ | (25.04.2022)
A)
A)
Avoid hard knocks to the measuring tool or dropping
u
it. After severe external influences and in the event of ab-
normalities in the functionality, you should have the
measuring tool checked by an authorised Bosch after-
sales service agent.
Certain ambient conditions fundamentally impair the
u
measuring results. These include, e.g. the proximity of
devices that generate strong electric, magnetic or
electromagnetic fields, moisture, metal building ma-
terials, foil-laminated insulation materials or conduct-
ive wallpaper or tiles. Therefore, also refer to other in-
formation sources (e.g. construction plans) before
drilling, sawing or routing into walls, ceilings or floors.
Hold the measuring tool by the intended gripping sur-
u
face (5) only, so as not to influence the measurement.
D-tect 120
2400–2483.5 MHz
90 % (non-condensing)
10.8 V, 12 V
4 × 1.5 V LR6 (AA) (with battery adapter)
0.50−0.61 kg
0 °C to +35 °C
–10 °C to +40 °C
–20 °C to +70 °C
GBA 10,8V...
GBA 12V...
GAL 12...
GAX 18...
Bosch Power Tools
60 mm
60 mm
60 mm
38 mm
±10 mm
50 mm
0.1 mW
2000 m
50 %
B)
2
5 h
5 h
C)
0.46 kg