8.5.2 Selection the Liebig anchor with floor pavement or tile surface
Hole diameter 17 mm in the baseplate
Liebig anchor
Anchor type
Hole depth (mm)
Min. anchoring depth (mm) b
Concrete thickness (mm)
Hole diameter (mm)
Component thickness (mm) e + f
Concrete quality
Number of anchors (pc.)
Torque of the anchors
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the details in the foundation
plans.
Similar value anchors and other known brands of anchor manufacturers can be used when considering the conditions.
(1) Declaration: normal reinforcement
A normal reinforcement is present if the axis separation in the area of the anchor with a rod diameter of ≥ 10 mm
is 150 mm, or for a rod diameter of ≤ 10 mm is 100 mm.
OPI_COMBI LIFT 480H_V4.2_DE-EN-FR-IT – Teile-Nr: 0030173
BM10-15/70/65
a
85
70
c
min. 140*
d
15
40 – 65
Min. C20/25 normal reinforcement
Depending on the lift type
40 Nm
BM10-15/70/100
85
70
min. 140*
15
65 – 100
1
40 Nm
BM10-15/70/140
85
70
min. 140*
15
100 – 140
40 Nm