8.5 Selection the anchor
8.5.1 Selection the Liebig anchor without floor cover
Hole diameter 17 mm in the baseplate
Liebig anchor
Anchor type
Hole depth (mm)
Min. anchoring depth (mm)
Concrete thickness (mm)
Hole diameter (mm)
Component thickness (mm)
Concrete quality
Number of anchors (pc.)
Torque of the anchors
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the details in the foundation
plans.
Similar value anchors and other known brands of anchor manufacturers can be used when considering the conditions.
(1) Declaration: normal reinforcement
A normal reinforcement is present if the axis separation in the area of the anchor with a rod diameter of ≥ 10 mm
is 150 mm, or for a rod diameter of ≤ 10 mm is 100 mm.
84
BM10-15/70/40
a
85
b
70
c
min. 140*
d
15
e
0 – 40
Min. C20/25 normal reinforcement
Depending on the lift type
40 Nm
OPI_COMBI LIFT 480H_V4.2_DE-EN-FR-IT – Teile-Nr: 0030173