Read the user manual carefully. Wrong installation can result in damage to the equipment and possible injury. If there are any un-
certainties, please contact DEFA or a qualified person. Fix the charger properly where it is to be installed. See drill guide on page 2.
Connect red wire to (+) end black wire to (-) The charger is intended for use with lead/acid, AGM and GEL batteries, but the battery
manufacturer's recommendations should always be taken into consideration.
NOTE: To make sure the correct charging voltages the charging cables must not be shortened or made longer.
• The charge output is protected against short circuiting and wrong connections.
• The charger does not draw current from the battery when the main power is not connected.
• Do not install the charger in a highly flammable environment.
• Do not charge a damaged battery.
• During charging, battery gas which is very explosive can be developed. Take care not to have sparks, open flames,
cigarettes or similar in the vicinity of the battery.
• The acid in the battery is corrosive and harmful. It damages clothes, metal and varnish. In case of spillage and contact
with skin, wash and rinse thoroughly with water and consult a doctor.
• Lead and other chemicals that are used in batteries are toxic. Wash skin and hands thoroughly after working with
batteries.
The charger is maintenance free. All batteries should be inspected monthly as a minimum to achieve the best possible safety. The
charging process is in such way that the batteries remain fully charged without further water consumption than normal evaporation.
The guarantee applies to faults in production and materials for 2 years from date of purchase. The customer must deliver the product
back to the place of purchase together with the receipt. The guarantee shall cease to apply if the charger is handled negligently, opened
or repaired by someone other than DEFA or an authorized representative of DEFA. DEFA has no other guarantee than this and will not
be responsible for other costs than those referred to, i.e. no possible additional costs. Neither is DEFA bound by any other guarantee.
Item no.:
Mains Voltage [VAC]
Temperature Range [ºC]
Charging Voltage* S1 [VDC]
Maintenance S2 [VDC]
Current [A]
Battery Size Max. [Ah]
IP rating [IP]
Weight [kg]
Measure (H/W/D) [mm]
Acceptance
* Temperature-compensated approx 5,0 mV/
DEFA confirms that these chargers satisfy relevant safety requirements according to prevailing regulations and standards.
INSTALLATION
SAFETY
MAINTENANCE
WARRANTY
TECHNICAL INFORMATION
706400
230
-20 +50
14,4/14,7
13,6
35
600
20
2,5
234x98x53
EN60335-1, EN60335-2-29, EN55014-1, EN55014-2, EN61003-3/2
C/cell. Ref. 25
C.
o
o
5