Error code
ER 03 and
Continuous sensor
continuous tone
activation; TC turn off
after 10 sec
ER20
Flash memory – TC error
ER22
Button evaluation
defective, UI shuts off
after 3.5-7.5 sec
ER31
Incorrect configuration
data or deviation between
generator and TC
ER36
NTC value defective on
TC; UI turns off
ER47
Communication error
between TC and induction
U400
Continuous tone Power
supply on inlet to high
E/2
Excess temperature of
the induction element
E/A
Error on the power board
E/6
Error on power board
E/8
Incorrect fan speed
E/9
Defective temperature
sensor on inductor
8. MAINTENANCE AND REPAIR
- Make sure that maintenance on electrical
components is carried out only by the
manufacturer or the customer service.
- Make sure that damaged cables are changed
only by the manufacturer or the customer service.
When contacting the customer service, please
provide the following information:
- type of fault
- appliance model (Art./Cod.)
- serial number (S.N.)
This information is given on the data plate. The
data plate is attached on the bottom side.
Error codes
Description
Water or cookware on the glass
over the touch control sensors
μC- defective
Short or open circuit in the area
of the button sensoric
New configuration of the
induction generator required
Short or open circuit of NTC
No or erroneous LIN
communication! (Slave does not
answer to request of master)
Incorrect connection of the
cooktop
Overload of cooktop or empty
boiled cookware
Component failure
No power supply or error on
power board
Error on fan left or right
Possible cause of error
9.TECHNICAL DATA
Product identification
Type: 4300
Model: GALILEO BK A830
Refer to the data plate placed on the bottom side
of the product.
The manufacturer provides continuously product
enhancements. For this reason, the text and
the illustrations in this manual may be changed
without notice.
Further information on technical data is available
on: www.faberspa.com
Remedy
Clean the control surface,
remove objects on the
sensors.
Replace TC
Replace TC
New configuration (Service
menu)
Replace TC
Connection cable not correctly
plugged in or defective.
Correct power supply
connection
Let system cool down.
Replace power board
1. check wiring
2. check filter board
3. replace power board
Air exhaust blocked, e.g. by
paper Replace Defective fan
Replace inductor Replace
power board
11