REFMATE operating instructions
7
Maintenance
The digital manifold requires maintenance work when used regularly:
Clean the screen and the housing surface with a cloth
and cleaning agent.
Do not use corrosive cleaning agents or solvents to clean
the unit. Weak household cleaners and soap suds may be
used.
The connectors and filling hoses must be visually
inspected for mechanical damage before each use and
replaced if damaged.
The seals of a manifold are naturally subject to
mechanical and ageing-related wear and tear. The
manifold must therefore be checked regularly by the
user for leaks.
If any valves are leaking, the piston must be replaced
(M4-6-04-R/10).
If the sight glass is leaking or scratched, it must be
replaced immediately. The replacement parts are
available as a service kit (M4-6-11, Part no. 4491018)
along with a removal tool (M4-6-11-T, Part no. 4493169).
Use the tool to remove the existing brass screw-ring and
then remove the gasket and sight glass. Insert the
replacement gasket and sight glass, and then screw in
the brass screw-ring with the tool. Care must be taken
not to over-tighten the screw-ring in order to prevent
damage to the glass. It should be tightened with a torque
between 3 Nm and 6 Nm.
7.1
Refrigerant update
Log in to the App
section.
Under refrigerants you will find the latest refrigerant
versions.
and go to the device update
English