IMPORTANT SAFETY INFORMATION
Installation Warnings
• Minimum clearance from the fireplace to combustible materials is 48 inches (121.9 cm) on
all sides. Do not place this fireplace under any overhead structure or vegetation.
• The normal inlet pressure for this fireplace is 7.0" W.C. (1.74 kPa). Maximum inlet pressure
is 10.5" W.C. (2.61 kPa). Minimum inlet pressure is 3.5" W.C. (0.87 kPa).
• A fireplace with a connection to a fixed piping system must conform with local codes, or in the
absence of local codes with The National Fuel Gas Code, ANSI Z223.1/NFPA 54, or International Fuel
Gas Code.
• Do not remove the feet from this fireplace.
• Do not place the fireplace on anything that blocks or seals the gap between the fireplace and the ground.
• Do not permanently secure the fireplace in any way or to any surfaces.
• Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
• Do not coil or hide the hose under the fireplace. The hose could be damaged if it touches hot surfaces.
Set Up Warnings
• Prior to each operation, check the hose assembly for evidence of excessive abrasion, wear or
damage. Use a handheld mirror, if necessary, to see the hose sections located below the unit.
• If the hose assembly is damaged, cracked, or cut, it must be replaced before using the fireplace.
The hose assembly must be replaced with a hose assembly specified by Real Flame.
Please contact Real Flame Customer Service at 1-800-654-1704 for assistance.
• Place the hose out of the pathways where people may trip over it. Do not place the hose
in areas where it may be accidentally damaged.
• Before each use, examine the burner and its components for dirt and debris. If cleaning is required,
use a pipe cleaning brush and compressed air. Also examine the area around the burner.
Any dirt or foreign material, such as spider webs, nests, leaves, etc., should be removed. If it is
evident that the burner is damaged, the fireplace must not be used, and the burner assembly
must be replaced. Please contact Real Flame Customer Service at 1-800-654-1704 for support.
In-Use Warnings
• NEVER LEAVE this fireplace unattended when in use.
• Do not burn solid fuels, such as charcoal briquettes, lump charcoal, manufactured logs, trash, leaves
paper, cardboard, any type of natural or treated wood, or any other materials in this fireplace.
• The use of alcohol, prescription or non-prescription drugs may impair your ability to safely
operate this fireplace.
• Always use in accordance with all applicable local, state, and national codes. Contact your
local fire department for details on outdoor burning.
• Do not use in windy conditions. High winds may cause the flame to extinguish.
• Some surfaces of this fireplace may become hot during use. Be careful and do not touch
surfaces until the unit has cooled.
• Do not attempt to disconnect the gas supply from the fireplace when the unit is in use.
• Do not sit on the fireplace.