Installation Instructions
3.
Align four mounting holes in RPME with four pilot holes.
IMPORTANT ! : When RPME is properly positioned, the
set screw access hole should be pointing directly at
target, or 180° AWAY from target.
4.
Secure RPME to structure using four #10-24 x 3" wood
screws (not included) and four 1/4" flat washers (not
included). (See Figure 7)
4
x 4
Figure 7
5.
Proceed to Installing Projector with Interface Bracket
section.
Installing to Concrete Ceiling
NOTE:
If installing RPME to anything other than a CPA
column, the CPA adapter portion must be removed
from RPME mount prior to installation. See CPA
Adapter Removal Section for details.
WARNING:
The RPME is designed to be mounted to a
concrete ceiling with a minimum thickness of 8" and a
maximum drywall covering of 5/8".
1.
Using the RPME as a guide, mark four mounting hole
locations on ceiling using a pencil or similar tool.
2.
Drill four 1/4" (6.4mm) dia. pilot holes to a depth of 2-1/2"
(64mm) deep. (See Figure 8)
3
1
x 4
2
3.
Align four mounting holes in RPME with four pilot holes.
IMPORTANT ! : When RPME is properly positioned, the
set screw access hole should be pointing directly at
target, or 180° AWAY from target.
WARNING:
Anchors (not provided) must be installed into
structurally sound solid concrete. Installation into hollow
concrete block, mortar, or concrete that exhibits cracking,
spalling, or other defects may result in failure of anchor and
serious personal injury or damage to equipment.
4.
Install four Toggler AF6 Alligator concrete anchors (not
included) by inserting into pilot holes and hammering in until
flush with mounting surface.
5.
Secure RPME to structure using four 1/4" flat washers and
four #10-24" x 3" wood screws (not included). (See Figure 9)
5
x 4
Ø 6.4mm
Pilot
(Ø 1/4")
hole
dimensions
64mm
(2-1/2")
Figure 8
4
Figure 9
RPME
x 4
7