Preparation - CHIEF RPME Elite Série Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions

PREPARATION

Locate Mounting Site
WARNING:
IMPROPER INSTALLATION MAY LEAD TO
PROJECTOR MOUNT FALLING CAUSING SEVERE
PERSONAL INJURY OR DAMAGE TO EQUIPMENT! It is
the installers responsibility to make certain the structure to
which the projector mount is being mounted is capable of
supporting five times the weight of the projector mount and all
attached equipment. Reinforce the structure as required
before installing the projector mount.
1.
Determine required position of the RPME projector mount.
2.
Determine required distance of the projector mount from the
screen using the projector specifications.
NOTE:
Proceed to Installing to 1-1/2" Threaded Extension
Column, Installing to Wood Framework, Installing
to Concrete Ceiling, or Installing to Threaded Rod
section, as appropriate.
INSTALLATION
Installing to a CPA Pipe
1.
Making sure holes are aligned on RPME's CPA adapter and
CPA column (not included), lift RPME into bottom opening
of CPA column. (See Figure 1)
2.
Install either one M6x16 button head screw (C) or security
screw (D) into hole on side of CPA pipe where the adapter
plate on CPA adapter is located. (See Figure 1)
3.
On the opposite side of CPA pipe, use the other M6x16
button head screw (C) or security screw (D) to secure
RPME (A) to CPA column. (See Figure 1)
3
CMA pipe
(not included)
1
CPA adapter
Figure 1
4.
Tighten security screw (access from bottom of RPME) (See
Figure 2) using a Phillips screwdriver until set screw cannot
be seen through set screw access hole in RPME. (See
Figure 2)
(C) or (D)
2
(C) or (D)
adapter
plate
hole on side
of adapter plate
Security screw
x 1
4
Figure 2
5.
Proceed to "Projector Installation" Section.
CPA Adapter Removal
NOTE:
If installing RPME to anything other than a CPA
column, the CPA adapter portion must be removed
from RPME mount prior to installation.
1.
Loosen set screw holding CPA adapter to RPME mount.
(See Figure 3)
2.
Turn CPA adapter counter-clockwise until threads are no
longer engaged with RPME. (See Figure 3)
3.
Remove CPA adapter from RPME. (See Figure 3)
3
Figure 3
RPME
(RPME bottom view)
CPA adapter
4
2
5

Publicité

Table des Matières
loading