Télécharger Imprimer la page

Bertazzoni B3H0 A7X Serie Instructions Pour L'utilisateur page 5

Publicité

Les langues disponibles

Les langues disponibles

Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Drop-in cooktop with 5 workyop burners model B3H0..(A or Q)7X(2 or 5)D
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L
Rear R
Rapid
Front L
Centre Inner
Dual
burner
Centre Outer
Drop-in cooktop with 6 workyop burners model B3K0..(Q or U)7X(2 or 5)
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L & C
Front C
Rapid
Rear R
Centre Inner
Dual
burner
Centre Outer
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until
the flame of the burner is regulated in the most suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Adaptation of the pressure regulator for use with different type of gas
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with
Natural Gas at a nominal outlet pressure of 4" w.c. or LP gas at a nominal outlet pressure of 11" w.c. and it is
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging
labels affixed on the appliance, package and Instruction booklet.
Inj. size
Gas
1/100mm
Type
92
NG
56
LP(Propane)
117
NG
73
LP(Propane)
155
NG
98
LP(Propane)
80
NG
50
LP(Propane)
N°2 x 130
NG
N°2 x 83
LP(Propane)
Inj. size
Gas
1/100mm
Type
0,92
NG
0,56
LP(Propane)
1,17
NG
0,73
LP(Propane)
1,55
NG
0,98
LP(Propane)
0,80
NG
0,50
LP(Propane)
N°2 x 1,30
NG
N°2 x 0,83
LP(Propane)
Pressure
Max Rate
[i.w.c.]
[BTU/h]
4"
3750
11"
3750
4"
6000
11"
6300
4"
10400
11"
11400
4"
11"
NG 17000
4"
LP
18800
11"
Pressure
Max Rate
[i.w.c.]
[BTU/h]
4"
3750
11"
3750
4"
6000
11"
6300
4"
10400
11"
11400
4"
11"
NG 17000
4"
LP
18800
11"
Min Rate
[W]
[BTU/h]
[W]
1098
900
264
1098
900
264
1759
1500
439
1845
1500
439
2046
2500
732
3339
2500
732
4980
900
264
5507
Min Rate
[W]
[BTU/h]
[W]
1098
900
264
1098
900
264
1759
1500
429
1845
1500
439
2046
2500
732
3339
2500
732
4980
900
264
5507
By-pass size
[1/100mm]
Regulated
29
Regulated
36
Regulated
47
Regulated
29
Regulated
65
By-pass size
[1/100mm]
Regulated
29
Regulated
36
Regulated
47
Regulated
29
Regulated
65

Publicité

loading

Ce manuel est également adapté pour:

B3h0 q7x serieB3k0 q7x serieB3k0 u7x serieQb36m500x