Table des Matières

Publicité

Indicator Light Function:
Arrow Symbols (Operation - Blue Light): This light illu-
minates and remains illuminated as long as the unit is
operational.
Bucket Symbol (Water Full - Red Light): This light illu-
minates under the following conditions;
1. When the internal water tank is not properly installed
inside the cabinet.
2. When the internal water tank is full. Water tank must be
emptied and replaced back in the cabinet before normal
operating conditions can resume.
Water Tank Operation:
Proper installation of the water tank is crucial in maintain-
ing reliable dehumidifier operation.
The water tank holds accumulated condensed water rout-
ed from the evaporator (cooling) coil during dehumidifier
operation.The water level inside the tank is controlled by
a float switch mechanism that automatically stops dehu-
midifier operation when the water level reaches a pre-
determined level.
When the water tank is full and /or incorrectly positioned
inside the cabinet, the (water full) red light flashes and a
signal (beep) sounds for 10 seconds.This condition
results in the immediate shut down of the dehumidifying
system. (compressor cycle terminated, however the fan
motor will continue to operate) The water tank must be
emptied and/or correctly re-positioned before dehumidifi-
er operation can resume NOTE: It may take several
minutes before operating conditions resume. This is
normal.
IMPORTANT: Never tamper with or attempt to defeat the
float switch mechanism. (as this will result in flooding)
Factory Default Setting:
When the unit is first connected to a power supply, the
electronic circuit board will automatically default to the
following factory settings;
Mode: Dehumidification
Humidity SET AIR Value: 60%
Fan Speed: Low
Custom Default Setting:
When you modify any or all of the factory default settings , your
new settings become the current default settings. When the unit
is switched "Off" or in the event of a power failure, all
your custom settings are retained and then restored once
the power is switched "On"/resumes.
7

Publicité

Chapitres

Table des Matières
loading

Table des Matières