en - Installation notes
Steam connection
The steam connection must only be carried out by a registered installation technician. The
information from the data plate, the wiring diagram and the documentation accompanying
the appliance must be noted and complied with when connecting steam-heated Miele ap-
pliances.
Condensate connection
The condensate separator must be installed so that when the system is not operating, the
heater bank is completely emptied. This means that no condensate may remain in the
heater bank. The installation of an inverted bucket condensate trap is recommended.
Air intake/exhaust air
The tumble dryer may only be operated when the ducting has been connected properly
and the room is sufficiently ventilated.
Accessory parts may only be fitted when expressly approved by Miele. If other parts are
used, warranty, performance and product liability claims will be invalidated.