5.1. Package shall be removed with care as the product has glass components. When
being unpacked, the showcase shall be positioned horizontally, with the maximum
inclination angle to not exceed 15°. When unpacking it, one shall make sure the product has
all of its components in line with section 3 hereof and that the showcase itself and all of its
components are in sound condition. The entire showcase and its components shall be
cleaned before installation.
5.2. Showcase installation location shall ensure proper access to the product at least
from two sides.
5.3. The product shall be operated in a room with the temperature in the range of +12 -
+25°С and the relative humidity of maximum 60%. The product shall not be exposed to
direct sunlight, Distance to the nearest heating appliances shall be at least two meters. The
showcase shall not be installed on a way of air ventilating streams, including from
conditioners.
5.4. The showcase shall be connected to 220 V 50 Hz mains in line with the applicable
Electrical Installations Code, Regulations for Operation of Consumer Electrical
Installations, and other regulations. Receptacle for connection of the showcase shall have a
ground contact. Voltage supply line shall utilize wires with the section of at least 1.5 mm
It shall have overcurrent protection. Before the product is switched on, it shall be kept at the
temperature of minimum 18°С for at least four hours. After the showcase is switched on,
one shall make sure it does not produce any foreign noise. The latter may be the evidence
of the product malfunction.
Attention! N neutral and L phase polarity shall be complied with when the product is
connected to
the mains.
5.5. Items to be cooled shall be loaded into the product after it is powered on and
when the required temperature in the effective volume of the product is achieved. Food
presentation height shall be maximum 50 mm.
ATTENTION! Glass shelf shall only be used for presentation of food items that
do not require cooling.
Temperature in the effective volume of the showcase can be adjusted with the
temperature controller.
5.6. It is not recommended to set the thermostat to the MAX position to avoid
continuous operation of the unit and glass fogging. Temporary fogging of glass may be
caused by the showcase operation in the conditions that do not comply with the
requirements specified in section 1 hereof (see clause 1.1, 1.2), which does not mean the
product malfunctions. In case of excessive build-up of snow cover on the evaporator box
due to increased air humidity or improper operation (overloading with moist products), the
showcase shall be defrosted by disconnecting it from the mains until it is completely
defrosted.