Noni - 1.5" Recessed Ceiling Prep
Two methods listed below to achieve cutout in ceiling for fixture installation:
Method 1: Without optional mounting pan
STEP 1
For remodeler-style installation - use hole saw to cut a 2" aperture hole in ceiling (figures 1A & 1B).
Method 2: With optional mounting pan
FIGURE 2A
1/2" EMT
SUPPLIED BY CUSTOMER
STEP 1
Determine mounting method based on building construction (figures 2A-2D).
STEP 2
For commerical spaces:
Slide EMT or U-Channel through appropriate features on mounting brackets (figures 2A-2C).
For suspended ceiling:
Position mounting bars over T-Grid. Secure by squeezing mounting tabs and/or by threading
safety cable through holes on mounting bars & T-Grid (figure 3).
For wood joist:
Line up bottom edge of hinged mounting bar with bottom of joist and fasten in place with provided
nail (figure 4). Then swing up frame and extend mounting bars as needed to reach opposite joist
and fasten in place.
INST-KV NONI 1.5in REC CEILING PREP
TITLE
04/06/22
DATE
93147493
DWG NO
2.00
FIGURE 1A
FIGURE 2B
3/4" X 1/2" CHANNEL
SUPPLIED BY CUSTOMER
REV
2
kurtversen.com | 781-294-0100 | techsupport@kurtversen.com
FIGURE 1B
FIGURE 2C
1-1/2" X 1/2" CHANNEL
SUPPLIED BY CUSTOMER
DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY
FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED
HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR
THE INSTALLATION OF IT, PLEASE CALL KURT VERSEN ENGINEERING AT
781-294-0100
2 of 6
2.00 TYP.
FIGURE 2D
RESIDENTIAL MOUNTING BAR
OPTIONAL