Télécharger Imprimer la page

Faults / Trouble-Shooting (For Users); Shut-Down; Environmental Requirements - Dimplex BWP 301 L Instructions D'installation Et D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

Should replacement of the protection anode (by a technician) be
necessary, the cylinder must be drained via the valve provided
(to be fitted during installation - see Appendix).
ATTENTION!
Malfunctioning protection anodes reduce the service life of the device!
8
Faults / Trouble-
Shooting (for Users)
The heat pump will not operate!
Please check whether
the plug is plugged in
the operating switch is switched on
the switches on the remote control are switched on
the socket is supplied with voltage
the air intake temperature is  8 °C
the heat pump has not been switched off via the temperature
controller
the hot water temperature has already been reached (or ex-
ceeds) 60 °C
Note for the technician:
Has the internal device fuse tripped?
The heat pump switches off prematurely (set
temperature has not been reached)
Please check whether
ducts have been bent or their openings have been sealed,
or whether any air filters are heavily contaminated (clogged)
Condensate does not drain properly (there is water
in or under the device)
Please check whether
the seal valve in the condensed water hose is contaminated
or clogged - clean it, if necessary; the valve can be easily re-
moved and replaced
ventilation is extremely reduced (bent duct / clogged air fil-
ter)
If the above questions cannot help you eliminate these faults,
please contact your technician or after-sales service.
www.dimplex.de
9

Shut-Down

Tasks to be carried out:
Disconnect the HW HP from the power source.
Completely shut off the water circuit (hot water, cold water
and circulation pipe) and drain the hot water cylinder.
10 Environmental
Requirements
During start-up and shut-down of the HW HP, all environmental
requirements regarding recovery, recycling and disposal of ma-
terials and components should be observed in accordance with
DIN EN 378.
10
E-9

Publicité

loading