English
Before
charging
While
charging
Charge
indicator
lamp
(RED /
BLUE /
Charging
GREEN /
complete
PURPLE)
Overheat
standby
Charging
impossible
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the Table 6, and batteries that have
become hot should be cooled for a while before being
recharged.
Rechargeable
Temperatures at which the battery
batteries
BSL1860
20
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light
for 0.5 seconds.
Blinks
(off for 0.5 seconds)
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 1 second.
(off for 1 second)
(BLUE)
Lights for 1 second. Does not light for
0.5 seconds.
Blinks
(off for 0.5 seconds)
(BLUE)
Lights continuously
Lights
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light
for 0.3 seconds.
Blinks
(off for 0.3 seconds)
(RED)
Lights for 0.1 seconds. Does not light
for 0.1 seconds.
(off for 0.1 seconds)
Flickers
(PURPLE)
(Intermittent buzzer sound: about 2
seconds)
Table 6
can be recharged
14°F – 122°F
(-10°C – 50°C)
Table 5
(3) Regarding recharging time (At 68°F (20°C))
Table 7 Charging time
Charger
Battery
BSL1860
NOTE
The recharging time may vary according to the
ambient temperature.
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
Plugged into power source
Battery capacity at less than
50%
Battery capacity at less than
80%
Battery capacity at more than
80%
Battery overheated. Unable
to charge. (Charging will
commence when battery cools)
Malfunction in the battery or the
charger
UC18YSL3
Approx. 38 min.