5.2 Gas connection
CAUTION!
Check this data before connecting the appliance to the gas cylinder.
Pressure reducing valves to be used between the gas cylinder and the
appliance must conform to the categories listed in the table below.
This appliance can be operated with the gases and related pressures described in
the following table. The identification label glued to the appliance clearly shows the
category (or categories) according to which the appliance has been adjusted.
CATEGORY AND COUNTRIES OF
DESTINATION
I3B/P(30)
AT BE DE DK FI GB NL NO PT SE SI
I3+ (28-30/37)
BE CH ES FR GB IE IT PT SI
MODEL
OVG340I
OV1800
OVN1800I
CAUTION!
During installation and connection, the gas conductor of the appliance
must not be subject to twisting, pulling or other stresses.
EN
NOMINAL AND COMPLETE
HEAT OUTPUT
kW - gr/h
1.6 - 115
1.1 - 80
1.1 - 80
Installation
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butane (G30)
37 mbar Propane (G31)
VOLUME OF AIR
REQUIRED FOR
COMBUSTION
m
/h
3
3.2
2.2
2.2
29