B. CONNECTION OF THERMOSTAT CABLE
1.
Connect the RED wire from relay box to the wire
coming from the "RC" terminal on thermostat.
Connect the YELLOW wire from relay box to wire
2.
coming from the "Y" terminal on thermostat.
3.
Connect the BLUE wire from relay box to wire
coming from the "H" terminal on thermostat.
Connect the ORANGE wire from relay box to wire
4.
coming from "G" terminal on thermostat.
5.
Use twist connectors to assure good connec-
tions.
10. INSTALLATION OF RETURN AIR
COVER
1. Remove Return Air Grille from the Return Air Cover.
2. Place the Return Air Cover up to Ceiling Template.
3. Install Cover to Template with #8x3/8"/9.5mm blunt
point phillips head screws provided (6 required).
4. Reinstall return Air Grille into Return Air Cover.
RELAY KIT
WIRING DIAGRAM
AIR CONDITIONER
FACTORY WIRING F
LINE
SPLICE
5. Install two (2) hole plugs into screw holes in back of return
air grille. Align tabs with mating notches and snap into
place.
This completes the Installation of the air conditioner. We
recommend that power be supplied to the air conditioner.
Check the unit for proper operation. Refer to the Operat-
ing lnstructlons of this manual for a description of air
conditioner operation.
FACTORY WIRING -
F I E L D WIRING 220/240v ------
FlELD WIRING 24V------
LINE SPLICE 0
START CAP
TERMINAL 4 IS USED FOR WlRE
CONNECTION ONLY AND NOT A
FUNCTIONAL PART OF START RELAY
TRANSFORMER
I
I
3104774.009
3104797.000