3.
Place Divider Plate up to bottom of Air Conditioner
base pan firmly. The foam tape on the divider plate
must seal to bottom of base pan.
Push Divider Plate firmly
onto template
Note: The adhesive on double sided tape is
extremely sticky. Divider Plate must be prperly
positioned before pressing in place.
With slight pressure then push divider plate against
4.
exposed double sided tape on ceiling template.
5.
Locate 7" x 18"/175mm x 460mm self-adhesive insu-
lation supplied with the Return Air Kit. Remove the
backing paper from the insulation and carefully stick
onto the ceiling template divider panel.
Excess width is intended to seal the divider plate
a.
to the sides of the 14"/355mm opening. This is to
prevent cold air discharge from circulating into the
Air Conditioner return air opening.
If the insulation is too high, stick the excess height
b.
of insulation to the Air Conditioner base pan.
not cover up unit rating plate.
adhesive
Note:
The
on insulation is extremely sticky.
Be sure part is located where desired before
pressing into place. We recommend pulling
off part of backing paper, locating part and
then removing backing paper as insulation is
pressed into place.
Place insulation in position
(Do not cover unit
9. CONNECTION OF POWER SUPPLY
A. CONNECTION OF 220 VOLT POWER SUPPLY
Disconnect ALL power before wire leads are
connected.
1.
Remove the junction box cover from the relay box.
2.
Route the power supply line through the connector
located at the junction box.
Connect the
3.
ACTIVE WIRE of power supply.
4.
Connect the
NEUTRAL WIRE of power supply.
Connect the
5.
to the EARTH/GROUND WIRE of power supply.
Note: Use appropriate sized twist wire connectors
to join power supply to unit wires. Tape the twist
wire connectors to the supply wiring to assure they
do not vibrate off.
6.
Tighten the strain relief onto the power supply line
to hold it firmly in place.
7.
Carefully push all excess wire back into the junc-
tion box. (See following illustration).
Do
18
in the junction box to the
black wire
in the junction box to the
red wire
in the junction box
green/yellow wire
JUNCTION BOX COVER