iCLASS SE / multiCLASS SE
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E
2
Wiring
Pigtail Reader
Pigtail
Terminal
Description
Yellow
P1-1
Beeper Input
Orange
P1-2
LED Input (GRN)
Black
P1-3
Ground (RTN)
Red
P1-4
+VDC
Drain
P1-5
Unused
Brown
P1-6
LED Input (RED)
Blue
P1-7
Hold Input
*
Tamper Output. When activated, output syncs to ground (default).
**
Dependent upon reader configuration.
See HTOG Wiegand and Clock-and-Data configurations for more information.
Flexible
Borne
Descripción
Amarillo
P1-1
Entrada de bíper
Naranja
P1-2
Entrada para LED Verde (GRN)
Negro
P1-3
Conexión a tierra
Rojo
P1-4
+VCC
Drenaje
P1-5
Sin uso
Marrón
P1-6
Entrada para LED Rojo
Azul
P1-7
Entrada de retención
*
Salida de sabotaje. Al activarse, la salida se sincroniza con tierra (predeterminado).
**
Depende de la configuración del lector.
Consulte las configuraciones de HTOG Wiegand y Clock-and-Data para obtener más información.
4
INSTALLATION GUIDE
C
ableado
C
âblage
f
iação
BEEP
GPI01
GRN
GPI02
GND
OC/TMPR
+VDC
DATA1/CLK
DRAIN
DATA0/DATA
RED
GPI03
HOLD
GPI04
P1
18 in
P2
(0.46 m)
Terminal Reader
Pigtail
Terminal
Description
Red / Green
P2-7
GPIO1 (RS232-T / RS485-FDX/HDX-A)
Tan
P2-6
GPIO2 (RS232-R / RS485-FDX/HDX-B)
Violet
P2-5
*
Open Collector Output / Tamper
White
P2-4
**
Wiegand Data 1 / Clock
Green
P2-3
**
Wiegand Data 0 / Data
Pink
P2-2
GPIO3 (RS485-FDX-Z)
Gray
P2-1
GPIO4 (RS485-FDX-Y)
Flexible
Borne
Descripción
Rojo/ Verde
P2-7
GPIO1 (RS232-T / RS485-FDX/HDX-A)
Canela
P2-6
GPIO2 (RS232-R / RS485-FDX/HDX-B)
Violeta
P2-5
*
Salida de colector abierto
Blanco
P2-4
**
Datos Wiegand 1 / Reloj
Verde
P2-3
**
Datos Wiegand 0 / Datos
Rosa
P2-2
GPIO3 (RS485-FDX-Z)
Gris
P2-1
GPIO4 (RS485-FDX-Y)
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
V
erdrahtung
C
ablaggio
布线
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Note: Previous iCLASS readers had reversed
RS-485 wiring ( P2-7 & P2-6 - A & B).
When upgrading to an iCLASS SE reader,
ensure proper connections as defined
below.
PLT-01579, A.3
配線
배선
П
ОдКЛючЕнИЕ ПрОвОдОв
ATTENTION