3.
Insert the two power wires into the two terminals on the
power connector block. The connection can be made with
either polarity.
Use a small slotted (5/64" or 2 mm blade width)
screwdriver to loosen and tighten the terminals.
4.
Attach the power connector block back into the receptacle
on the device.
Warning — This product is intended to be supplied by a UL
Listed Power Unit marked "Class 2" or "LPS" or "Limited
Power Source" with output rated 12 VDC or 24 VAC, 6 W
min. or PoE rated 48 VDC, 6 W min.
When you select the wire used to provide power, be sure to select a
gauge that is heavy enough for the wiring distance. Refer to the
following table for the maximum wire length for different wire gauges.
Table:Wire Length for Different Wire Gauges
Wire Gauge
AWG
24
22
20
18
16
6
All manuals and user guides at all-guides.com
mm
2
0.2
0.33
0.5
0.82
1.3
Maximum Run Length
(ft [m])
24 VAC
164[50]
267[81]
428[130]
680[207]
1071[326]
12 VDC
43[13]
71[21]
114[34]
181[55]
285[87]

Publicité