Light Tower
Power Cable
Tower Rotation
Light Fixtures
LED
Color Temperature
Power Consumption - per
Fixture
Lumens - per Fixture
Electrical
Frequency
Rated Prime Power Output
Alternator
Phase
Note*
Automatic Lighting - Sequenced
Lighting System (SLS)
Available Outlets
Engine - Kubota D1005
Specification
Manufactuer
Model
Type
Displacement
Aspiration
Emissions
Power Output - Prime
Fuel System
Starting Aid
Engine Electrical System
Engine Alternator
Number of Batteries
Battery Size
Battery Type
Battery Rating
Automatic Low Oil Pressure
Shutdown
Automatic High Water
Temperature Shutdown
28
Coiled cable secured at top of
sections to minimize possibility of
tangling
Complete tower rotates 345°
5000K
350 W
57,140
60 Hz
60 Hz - 6,0 kW
60 Hz - 240/120 VAC capacitor
regulated
1-phase
There is a permanent conductor
between the generator (stator
winding) and the frame
Automatically turns lights on after
engine start and delays engine
shutdown to turn off lights first to
prevent generator from shutting down
under load.
20A 120V duplex GFCI outlet (NEMA
5-20R)
30A 240V 4-wire twist lock (NEMA
L14-30R)
30A 120V RV outlet (NEMA TT-30R)
Imperial
Metric
Kubota
D1005
Liquid-Cooled Three Cylinder Diesel
61 cu in
1.001 L
Naturally aspirated
EPA Tier 4 Final
11.7 Hp @ 1800
8,7 kWm @ 1800
rpm
rpm
Indirect Injection
Glow Plugs
12 Volt DC
30 A
1
Group 24
Standard - Lead Acid
Optional - Absorbed Glass Mat
(AGM)
525 CCA @ 0°F (-18°C)
775 CCA @ 0°F (-18°C)
7 PSI
48 kPa
230°F
110°C
Engine - Kubota D1005
Specification
Fuel
Required Engine Oil Type
Engine Oil Capacity - with Filter
Required Engine Coolant Type
Coolant System Capacity
Coolant Overflow Reservoir
Capacity
Service Interval - Oil Change &
Filter
Service Interval - Fuel Filter
Service Interval - Air Filter
Note*
Engine - Kubota D1105
Specification
Manufactuer
Model
Type
Displacement
Aspiration
Emissions
Power Output - Prime
Fuel System
Starting Aid
Engine Electrical System
Engine Alternator
Number of Batteries
Battery Size
Battery Type
Battery Rating
Automatic Low Oil Pressure
Shutdown
Automatic High Water
Temperature Shutdown
Fuel
Required Engine Oil Type
Imperial
Metric
North America - diesel fuels that meet
ASTM D975 for Ultra Low Sulfur
Diesel (ULSD) are required. ULSD
has a maximum sulfur content of 15
parts per million (PPM) or 15 mg/
kg. Diesel fuel may be No. 1-D or
No. 2-D. Refer to Engine Operator's
Manual for detailed information.
10W-30 API CK-4 (CJ-4, CI-4, CI-4
Plus) or its equivalents
5.4 US qts
5,1 L
Nitrite Free Extended Life Coolant,
Organic Acid Technology (OAT),
2-EHA Free
5.0 US qts
4,7 L
1.1 US qts
1,0 L
First Oil & Oil Filter Change - 50 hr
All Other Oil & Oil Filter Changes -
1,000 hr*
400 hrs
Refer to Engine Op Manual
Engine oil must be checked prior to
operation and refilled if necessary
Imperial
Metric
Kubota
D1105
Liquid-Cooled Three Cylinder Diesel
69 cu in
1.123 L
Naturally aspirated
EPA Tier 4 Final
13.5 Hp @ 1800
10,1 kWm @
rpm
1800 rpm
Indirect Injection
Glow Plugs
12 Volt DC
40 A
1
Group 24
Standard - Lead Acid
Optional - Absorbed Glass Mat
(AGM)
525 CCA @ 0°F (-18°C)
775 CCA @ 0°F (-18°C)
7 PSI
48 kPa
230°F
110°C
North America - diesel fuels that meet
ASTM D975 for Ultra Low Sulfur
Diesel (ULSD) are required. ULSD
has a maximum sulfur content of 15
parts per million (PPM) or 15 mg/
kg. Diesel fuel may be No. 1-D or
No. 2-D. Refer to Engine Operator's
Manual for detailed information.
10W-30 API CK-4 (CJ-4, CI-4, CI-4
Plus) or its equivalents
www.allmand.com